Measurement procedure
82 A0293_06_E00_03 HBM: public MP85A
Tip
You can find a more detailed description of all evaluation criteria with exam
ples, diagrams and tips and tricks in the online help of the PME Assistant and
the add-on software modules. Launch the PME Assistant and press F1 to open
Help.
8.6 Measurement programs (parameter sets)
You can enable a total of 31 measurement programs for 31 different
workpieces from the MP85A process controller's internal (flash) memory. A
measurement program comprises a workpiece-specific parameter set, the
amplifier settings for the sensors, measurement acquisition and saving, the
assignment of the digital inputs/outputs and the evaluation methods.
The parameter sets are imported from the flash memory of the MP85A process
controller to the RAM via digital input/outputs, bus commands or the PME
Assistant (section10.6) or INDUSTRYmonitor programs.
Important
Parameter sets may only be switched or imported after the end of a process,
not during a measurement. You can only start the next process once parame
ter set switchover is complete (also see section 10.1, Machine control system).