4 Planning and installation – Installing the heating system
52
2. Remove the cover of the cleaning system motor (1).
3. Set the front boiler cladding (2) on the support plate on the front
side of the boiler.
4. Lay the cable for the drive of the automatic cleaning system (2)
between the plate (1) and the insulation (3) of the front cladding,
so that it doesn't contact any moving parts of the automatic
cleaning system.
5. Mount the front cladding on the boiler with the flat-headed
screws.
6. Guide the cable (3) of the automatic cleaning system through the
upper slot (1) and into the control cabinet (2).
7. Mount the cover of the cleaning system motor back onto the front
cladding.
āœ“ The front cladding has been attached.
Figure 4/25 - Attaching the front cladding
3
1
2
Figure 4/26 - Connecting the cleaning system
2
3
1