July 2010 11 – 137
8 Confirm the setting. --> The iTNC 530 offers the path and file name
PLC:\PLCMEM.A.
(If required, you can change the path and file name and also save more than one
file on the hard disk.)
8 Confirm the file name. -->The states and contents of the PLC markers/words are
stored on hard disk in the file specified.
8 Exit the PLC mode.
Playing back the
data into the RAM
8 Call the PLC mode. --> See “Calling the PLC mode” on page 11 – 115.
8 Scroll through the soft-key row.
8 Call the TABLE function.
8 Scroll through the soft-key row.
8 Press this soft key. --> The iTNC 530 offers the path and file name
PLC:\PLCMEM.A.
(If the remanent PLC markers and words were stored in another file, the file
name must be indicated here.)
Figure: Write back non-volatile PLC markers and words
8 Confirm the file name. --> The saved conditions or contents of the PLC markers/
words are written back into the RAM.
8 Exit the PLC mode.