18 – 280 HEIDENHAIN Service Manual iTNC 530
18.1.3 Troubleshooting
To find out, whether the connected encoder or the interface of the control is defective, the
interchange method can be used. Use the interface of a working axis for this purpose.
Example Error in X axis. position encoders connected to MC
Example machine
parameters
Block diagram
For trouble shooting do not connect obviously defective controls (e.g., position encoder with
short circuit after entering of humidity) to other interfaces (e.g., X1-X6, X35-X38) of the
control.
MP 100.x = CZYX (X = 1st axis, Y = 2nd axis, Z = 3rd axis, C = 4th axis)
MP 110.0 = 1 (X-axis at X1 input)
MP 110.1 = 2 (Y-axis at X2 input)
MP 110.2 = 3 (Z-axis at X3 input)
MP 110.3 = 4 (C-axis at X4 input)
MP 115.0 = %0000000000 (all inputs 1 Vpp)
MP 115.1 = %0000000000
MP 115.2 = %0000000000 (all inputs 50 kHz)
Always switch both the cable and the interface assignment by machine parameter!
MC:
Position encoder inputs can be assigned in any order.
CC 424 (B):
On the main DCB and on the auxiliary DCB the position encoder inputs can be assigned in
any order.