July 2010 19 – 321
19.7 Retraction after an Error with Control Reset
General
information
The sequence of the axes to be referenced can be defined by the operator if the machine
manufacturer permits the axes to be moved with the external axis direction keys.
If necessary, the referencing can also be deselected, See “Deselecting the Reference Run for
Axes” on page 19 – 320.
Tilted axes If the tool is tilted, it should be retracted in the respective angular position.
As of NC software version 34049x-02 with feature content level L2 it is possible to define
the current tool axis direction as the only traverse direction:
8 Perform a warm or cold start of the control.
8 Acknowledge the Power interrupted message. --> The message Relay ext. dc voltage
missing is displayed.
8 Press the button Control ON.
8 Press the 3-D ROT soft key and a new window Tilt the Working Plane
appears.
8 Place the cursor on the line Manual operation.
8 Press the TOOL AXIS soft key.
Figure: Setting the tool axis for retracting in a tilted system
It is the machine operator's task to retract the tool!
If you have any questions, contact the machine manufacturer!
The manufacturer can enable this function in MP 7503 with value 1.