17.5.2 Supply voltage for PLC outputs on the MC
X44:
PLC supply voltage
Pin layout on the MC 42x (B/C):
Error message If the 24 V power supply (which cannot be shut off via emergency stop) is missing at X44, the
error message Supply voltage missing at X44 appears.
The corresponding PLC outputs do not function. Depending on the PLC program of the machine
manufacturer, PLC error messages are displayed.
Connecting
terminal
Pin layout PLC outputs
1 +24 V cannot be switched off via EMERGENCY
STOP
O24 to O30
2 +24 V can be switched off via EMERGENCY
STOP
O16 to O23
3O0 to O15
40 V