July 2010 25 – 427
25.7 Corrective Action
Cleaning Use standard cleaning agents to clean transmitter/receiver units.
Readjusting
the SE
If required, realign the transmitter/receiver unit.
Exchange of
components
If required, replace the (rechargeable) battery, the broken stylus (of TS), the damaged contact
plate (of TT), the defective cable, etc.
Recalibration Check the accuracy of the touch probe system after exchanging the stylus, the contact plate,
and of course after a collision. Perform a recalibration.
Consult the machine operator, the machine manufacturer or your HEIDENHAIN service agency!
Returning the touch
probe
Return defective touch probes and those that impair the function of the control for examination.
Returning the
control
If you have found that the touch probe interface of the control is defective (connector X12, X13),
replace the MC. --> See “Exchange of HEIDENHAIN Components” on page 28 – 523.
A detailed description of the visual status check, of the beam direction, of battery
exchange, stylus exchange, centering, specifications, etc. can be found in the mounting
instructions of the touch probe!
When you exchange the battery, pay attention that the polarity is correct.
After the stylus (of TS) or the contact plate (of TS) has been exchanged, the touch probe
must be calibrated again.
A detailed description of the visual status check, of the beam direction, of battery
exchange, stylus exchange, centering, specifications, etc. can be found in the mounting
instructions of the touch probe!
If required, follow the instructions of the machine manufacturer!
A detailed description of the visual status check, of the beam direction, of battery exchange,
stylus exchange, centering, specifications, etc. can be found in the mounting instructions
of the touch probe!
If required, follow the instructions of the machine manufacturer!
A TL Micro laser touch probe system must/should be recalibrated under the following
conditions:
After a commissioning, cleaning or adjustment
Directly before precise measurements