July 2010 30 – 617
30.4.12 Display and operation
MP Function and input SW version
and
behavior
MP7210 Programming station
Input: 0: Controlling and programming
1: Programming station with PLC active
2: Programming station with PLC inactive
3: Programming station with PLC and emergency stop active
CN123
340 49x-02
MP7212 Power interrupted message
Input: 0: Acknowledge the Power interrupted message with CE key
1: Power Interrupted message does not appear
PLC
RUN
CN123
MP7220 Block number increment for ISO programs
Input: 0 to 250
PLC
RUN
CN123
MP7224 Lock specific file types
Input: 0: Do not disable
1: Disable
Bit 0 – HEIDENHAIN programs *.H
Bit 1 – ISO programs *.I
Bit 2 – Tool tables *.T
Bit 3 – Datum tables *.D
Bit 4 – Pallet tables *.P
Bit 5 – Text files *.A
Bit 6 – HELP files *.HLP
Bit 7 – Point tables *.PNT
PLC
RUN
CN123
MP7224.0 Disabling soft keys for file types
MP7224.1 Protecting file types
MP7224.2 Disable the EDIT ON/OFF soft key 340 422-07,
340 480-07
MP7225 Disable Windows drives in the TNC file manager
Format: ABCDEFGHIJKLMNOPQRSTUVWXYZ
Input: If there are more than one drive, they are entered without spaces, e.g.
MP7225 = CDE
340 480-06
PLC
RUN
MP7226.0 Reserved PLC
RUN
CN123
MP7226.1 Size of the datum table
Input: 0 to 255 [lines]
MP7229 Properties of the NC program PLC
RUN
CN123
MP7229.0 Line number for program testing
Input: 100 to 9999
MP7229.1 Program length up to which FK blocks are permitted
Input: 100 to 9999