EasyManua.ls Logo

HEIDENHAIN ITNC 530 - Page 27

HEIDENHAIN ITNC 530
696 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2010 4 – 27
The columns in the ERR window have the following meanings:
The individual error messages can be selected with the cursor; the open help window shows
the appertaining text.
Column Description
Number Error number (–1: no error number defined), issued by HEIDENHAIN or your
machine tool builder
Class Error class. Defines the reaction of the control:
ERROR
Program run is interrupted by the iTNC
FEED HOLD
The feed-rate release is canceled
PGM HOLD
The program run is interrupted (the control-in-operation symbol blinks)
PGM ABORT
The program run is interrupted (INTERNAL STOP)
EMERG. STOP
EMERGENCY STOP is set off
RESET
iTNC executes a system restart
WARNING
Warning message, program run resumes
INFO
Info message, program run resumes
Group Error source.
GENERAL
General error
OPERATING
Error during machining and machine traverse
PROGRAMMING
Error during programming
PLC
PLC error message of the machine manufacturer
Error
message
Displayed error text

Table of Contents

Other manuals for HEIDENHAIN ITNC 530