July 2010 4 – 39
B900 CC%d
supply voltage %d
The Vcc supply voltage (x) was out of range.
+4 = Undervoltage Vcc (+5 V)
Excessive load from external components
(e.g. encoders).
+6 = Overvoltage Vcc
(+5 V).
The power supply unit is defective.
+14 = Undervoltage Vcc (+15 V)
The power supply unit is defective.
+16 = Undervoltage Vcc (+15 V)
The power supply unit is defective.
-14 = Overvoltage Vcc
(-15 V).
The power supply unit is defective.
-16 = Overvoltage Vcc
(-15 V).
The power supply unit is defective.
Measure supply voltage Vcc (x).
Vcc (+5 V) < +4.75 V Check encoder
connections.
Vcc (+5 V) > +5.50 V Exchange power
supply unit.
Vcc (+15 V) < +14.25 V Exchange power
supply unit.
Vcc (+15 V) > +16.50 V Exchange power
supply unit.
Vcc (-15 V) < -14.25 V Exchange power
supply unit.
Vcc (-15 V) > -16.50 V Exchange power
supply unit.
See “Power Supply” on page 17 – 251
BA00 CC%d
operating
temperature %d
The temperature inside the LE was out of
the permissible range. (-128... 0...+127 =
Measured temperature value [°C] )
Temperature sensor on PCB is defective.
Insufficient ventilation of the electrical
cabinet (fan defective).
The ambient temperature is too high or too
low.
Check the ventilation conditions.
See “Information Menu” on page 17 – 267
See “Annex: Monitoring Functions” on page
3 – 661
See “Temperature” on page 6 – 75
C003 MC/CC%d
system clock
mismatch
Hardware error (quartz generator)
Software error
Exchange the drive control board or
processor board.
Check the software version.
C004 Undefined
interrupt
Software error
Hardware error: Disturbance results in
internal interrupt
Switch off the machine.
Switch on the machine.
Check the software version.
Check the grounding.
C005 Unknown
hardware
identifier
Software does not fit the hardware.
Hardw
are defective
Check the software
version.
Exchange drive control board.
C007 DC-link
voltage too low
Inverter defective
Line power interrupted
Check your line power supply.
Check the inverter.
See Service Manual “Inverter Systems and
Motors“
C00A PWM
triangular signal
error
Hardware error: Triangular signal does not
oscillate or it oscillates at the wrong
frequency
Exchange drive control board.
Inform your service agency.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions in
the manual
Additional information and descriptions in
the manual