July 2010 4 – 43
C400 Line count
error <axis>
Line count from the motor table does not
match the downloaded values.
Check machine parameter
(distance of one motor revolution and
distance for the number of signal periods).
Check the motor table (columns TYPE and
STR).
Check speed encoder.
See “Speed Encoders” on page 18 – 293. See “Speed Encoders” on page 18 – 293.
C410 Rotor
position <axis>
undefined
Contamination of the speed encoder (Zn
track).
Speed encoder cable defective.
Motor control board defective.
Speed encoder defective.
Exchange the motor.
Check the speed encoder cable.
Exchange the motor drive control board.
See “Speed Encoders” on page 18 – 293. See “Speed Encoders” on page 18 – 293.
C430 Ctrlr
parameters
incorrect %s
Feedforward-control parameters are set
incorrectly (acceleration, friction).
Excessive acceleration.
Controller parameters are set incorrectly (Ki,
Kp, Kd).
Filters set incorrectly (band rejection, low
pass).
Inverter defective (IGBT).
Incorrect motor selected in motor table.
Check the adjustment of the axes.
Check the inverter.
See “Sequence for Finding Errors in the
Control Loop” on page 6 – 62.
See Service Manual Inverter Systems and
Motors.
C430 Error of
position input
<axis>
Position encoder input does not exist.
Position encoder input not connected
correctly.
Position encoder input defective.
Install position encoder input.
Check connection of the position encoder
input.
Exchange position encoder input.
See “Position Encoders” on page 18 – 277.
C440 PWM
frequency <axis>
incorrect
PWM frequency within a control group is
incorrect.
Check the machine parameters for PWM
frequency.
PWM frequency > 5000 Hz only with
suitable hardware and only with PWM
outputs X51, X52, X57 or X58.
PWM freque
ncy <= 5000 Hz must be
identical within the control group.
PWM frequency > 3200 Hz
C450 Wrong
encoder <axis>
Entry in column SYS of the motor table
incorrect.
Speed encoder cable defective.
Speed encoder defective.
Motor control board defective.
Check the motor table (column SYS).
Check the speed encoder cable.
Exchange the motor.
Exchange the motor drive control board.
See “Speed Encoders” on page 18 – 293. See “Speed Encoders” on page 18 – 293.
C460 Motor
speed too high
<axis>
Motor not controllable Check the software version.
Inform your service agency.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions in
the manual
Additional information and descriptions in
the manual