July 2010 4 – 45
Operating
parameters
erased
This error message is displayed if the
machine parameters are deleted and the
PLC program is missing.
Enter new operating parameters.
See “Restoring Data” on page 13 – 197.
Movement
monitoring error in
<axis> A
The axis is moving at least 4 times slower or
faster than commanded by the nominal
speed command output.
Large backlash
Overloaded driver
Insufficient lubrication
Mechanical stiffness
Machine vibration
For analog axes: Servo defective
Check machine parameter 1140.x.
Remove any large backlash.
Check the lubrication
Remove mechanical stiffness
Analog axes: Check the servo
Inform your service agency.
See “Sequence for Finding Errors in the
Control Loop” on page 6 – 62.
Movement
monitoring error in
<axis> B
The motor is moving while the axis slides
are stationary or vice versa.
Excessive difference between the positions
calculated from the position encoder pulses
and the speed encoder pulses.
Excessive backlash
Defective coupling, gear, etc.
Belt torn
Check MP1144.x
Check the backlash
Repair the defective coupling, gear, etc.
Replace the belt
Inform your service agency.
See “Sequence for Finding Errors in the
Control Loop” on page 6 – 62.
CC%d +5V LE out
of tolerance
The 5V power supply of the LE is outside the
permissible tolerance range.
Inform your service agency.
See “Power Supply” on page 17 – 251.
See “Error Localization by Process of
Exclusion” on page 6 – 66.
See Service Manual Inverter Systems and
Motors
CC amplitude too
low %.2s
See "Position encoder %2: Amplitude too
small"
See "Position encoder %2: Amplitude too
small"
CC frequency too
high %.2s
The maximum input frequency was
exceeded at an encoder input.
Check encoder signal input
frequency.
See “Further
Examination of Position and
Speed Encoders” on page 18 – 308.
CC%d NC
temperature out
of tol.
The temperature inside the LE is outside the
permissible tolerance range.
Ensure adequate ventilation in the electrical
cabinet.
See “Information Menu” on page 17 – 267.
See “Temperature monitoring” on page 3 –
674.
See “Temperature” on page 6 – 75.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions in
the manual
Additional information and descriptions in
the manual

Table of Contents