28 – 536 HEIDENHAIN Service Manual iTNC 530
8 Enter a value for the new machine parameter.
8 The parameter is not required. --> Delete this MP or mark the parameter as comment so it
remains in the machine parameter list.
8 After each change, try to activate the machine parameter list with END.
If the MP list is complete, the iTNC 530 restarts.
Reset non-volatile
PLC markers and
words
8 Restart the control, do not acknowledge the Power interrupted message.
8 Write the non-volatile PLC markers and words from the hard disk to the RAM of the new
control. --> See “Non-Volatile PLC Markers and Words” on page 11 – 136.
Restoring the
original state of
the machine
If necessary, you may ...
Recalibrate the touch probes.
Initialize the swivel head again
Initialize the tool changer again.
Contact the machine manufacturer for information!
Functional test
8 Check the machine functions (with the aid of the machine operator).
Creating a machine
backup
If changes were made to the machine or control (e.g., new machine parameters have been
added), you should create a current machine backup. --> See “Backup on an External Data
Medium” on page 13 – 192.
Removing the
defective MC 422
8 Replacement controls are delivered with a form which you can use to provide information on
the error of the defective control.
Please fill in this form and attach it to the housing of the MC 422.
8 Check whether the hard disk is secured by a shipping brace.
8 Pack the defective MC 422 in the original packaging of the new MC 422.
8 Return the defective MC 422 to the machine manufacturer or to your HEIDENHAIN
service agency.
Note
Comments on the new MPs can be found in the text file READ_MP.A or READ_MP.A in path
PLC:\JH\ ...
Contact the machine manufacturer for more information!
If required you can add comments on the function of the new parameters in the MP list.
Note
On machines with analog axes, an offset fine adjustment should be performed with the
HEIDENHAIN code number after the exchange of the control.
--> See “Adjusting the electrical offset (drift adjustment)” on page 20 – 349.