The machine is in the mode
Cross over reference
points which is neither
possible with the NC START
key nor with the axis
direction keys.
Inverter system is not
ready for operation.
Check whether the
inverter system is ready.
See “Checking the
readiness of the inverter
system” on page 16 –
243.
During reference run, the
machine moves to the limit
switch.
The trip dogs for direction
reversal during reference
run are defective.
Check the motor load. See “Reference Run” on
page 19 – 317.
During reference run, the
machine moves to the
mechanical stop (for
machines without limit
switch).
An error message is
sometimes displayed, e.g.
8640 I2T value of motor is
too high ...
The machine was
switched off at the wrong
position.
Referencing with axis-
direction keys (no
automatic reference mark
traverse)!
See “Reference Run” on
page 19 – 317.
The machine executes the
reference run properly but
stops at a wrong position.
A wrong reference mark
was evaluated.
When executing a
reference run via the
motor encoder, the
switching signal is too
close to the requested
reference mark.
A magnet of scale is
shifted or defective.
The ref. mark selector
plate of a scale is shifted.
The enamel over a ref.
mark of a scale was
removed or is damaged.
Readjust the trip dog for
reference end position.
Readjust the magnet
(outside or inside the scale
housing) and fix it with
distance holders.
Readjust ref. mark
selector inside the scale
housing with special
slider.
Lacquer the ref. mark not
to be evaluated again or
replace the scale.
See “Readjusting the trip
dog for reference end
position” on page 18 –
305.
STIB ("Control-in-operation =
"*" in status display) remains
in place even though
positioning appears to be
completed.
In the automatic operating
modes the next NC block is
not executed; the NC
program gets caught up.
Axis did not reach the
positioning window.
Excessive drift of analog
axes
Approach behavior of axis
not optimized.
Perform drift adjustment
Re
optimization o
r new
optimization of the axis by
the machine manufacturer
See “Interface to the
Drives” on page 20 – 323.
"Vibrating" axes, sometimes
connected with loud noises
Poor shielding or
grounding
Connectors on grounding
terminal X131 of infeed/
regenerative module
(Simodrive 611D) not
properly wired
Grounding terminal X131
of power supply module
(Simodrive 611D) or
grounding connection
damaged
Check the grounding of
your machine; consult
your machine
manufacturer.
Ensure that all grounding
clamps are secure.
Check the shielding or the
covers.
See “Notes and Tips” on
page 6 – 72.
See “Exchange of
HEIDENHAIN
Components in the
SIMODRIVE System” on
page 28 – 554.
The following error is too
high at axis standstill.
Electrical offset of analog
axes
Carry out offset
adjustment.
See “Adjusting the
electrical offset (drift
adjustment)” on page 20 –
349.
Error Possible cause of error Measures for error
diagnosis and/or
corrective action
Descriptions in this
manual