July 2010 30 – 607
MP4042 PLC output to be set after shutdown
Input: 0 to 31
340 420-03
PLC
RUN
MP4043 Delay during shutdown for the PLC to execute final actions
Input: 1 to 60 [s]
0: No delay
340 490-04
PLC
RUN
MP4044 Switch off outputs that cannot be switched off by emergency stop after 250-ms delay
Input: %xxxxxxxx
Bits 0 to 7 correspond to O16 to O23
0: Do not switch off output with delay
1: Switch off output with delay
340 422-07,
340 480-07
Only until
340 422-09,
340 480-09
PLC
RUN
MP4045 Switch off outputs that cannot be switched off by emergency stop after 250-ms delay
Input: % xxxxxxx
Bits 0 to 6 correspond to O24 to O30
0: Do not switch off output with delay
1: Switch off output with delay
340 420-08
Only until
340 422-09,
340 480-09
PLC
RUN
MP4050.0-8 Traverse distance for lubrication of axes 1 to 9
Input: 0 to 99 999.999 [m or 1000°]
PLC
RUN
MP4060.0-3 Outputs that are to be switched off with the delay from MP4061.x when all outputs are
switched off
Input: 0 to 30 [no. of the output]
–1: Do not switch off any outputs with delay
340 422-09,
340 480-09
PLC
MP4061.0-3 Delay time for switching off the outputs in MP4060.x
Input: 0 to 5.000 [s]
340 422-09,
340 480-09
PLC
MP4070 Compensation amount per PLC cycle for lagged-tracking axis error compensation
Input: 0.0001 to 2.0000 [mm]
PLC
RUN
MP4110.0-47 Run time PLC timer T0 to T47
Input: 0 to 1 000 000.000 [s]
PLC
RUN
MP4111.96-x Run time PLC timer T96 to x (defined in OEM.SYS)
Input: 0 to 1 000 000.000 [s]
PLC
RUN
MP4120.0-47 PLC counter preset value
Input: 0 to 1 000 000.000 [s or PLC cycles, depending on MP4020, bit 11]
PLC
RUN
MP4130.0
MP4130.1
MP4130.2-5
Number of the high-speed PLC input for switching off the monitoring functions
Reserved
Numerical designation for fast PLC inputs
Input: 0 to 255 [no. of the PLC input]
MP Function and input SW version
and
behavior