8.5 Message List
115
8
Chapter 8 RS-232C/GP-IB Interfaces
Statistical Functions
:CALCulate:STATistics:STATe
1/ 0/ ON/OFF Sets statistical calculation function ex-
ecution
133
:CALCulate:STATistics:STATe?
ON/ OFF Queries the statistical calculation
function execution setting
133
:CALCulate:STATistics:CLEAr
Clears statistical calculation results 133
:CALCulate:STATistics:RESistance:NUMBer?
<Total data count>,
<Valid data count>
Queries the resistance data count 134
:CALCulate:STATistics:VOLTage:NUMBer?
<Total data count>,
<Valid data count>
Queries the voltage data count 134
:CALCulate:STATistics:RESistance:MEAN?
<Mean> Queries the resistance mean value 134
:CALCulate:STATistics:VOLTage:MEAN?
<Mean> Queries the voltage mean value 134
:CALCulate:STATistics:RESistance:MAXimum?
<Maximum value>,
<Data No. of Maximum
value>
Queries the resistance maximum val-
ue
135
:CALCulate:STATistics:VOLTage:MAXimum?
<Maximum val-
ue>,<Data No. of Maxi-
mum value>
Queries the voltage maximum value 135
:CALCulate:STATistics:RESistance:MINimum?
<Minimum value>,
<Data No. of Maximum
value>
Queries the resistance minimum val-
ue
135
:CALCulate:STATistics:VOLTage:MINimum?
<Minimum value>,
<Data No. of Maximum
value>
Queries the voltage minimum value 135
:CALCulate:STATistics:RESistance:LIMit?
<Hi count>,<IN count>,
<Lo count>,
<Measurement fault
count >
Queries comparator results of resis-
tance measurement
136
:CALCulate:STATistics:VOLTage:LIMit?
<Hi count>,<IN count>,
<Lo count>,
<Measurement fault
count >
Queries comparator results of voltage
measurement
136
:CALCulate:STATistics:RESistance:DEViation?
<
n
>, <
n-1
>
Queries standard deviation of resis-
tance measurement
136
:CALCulate:STATistics:VOLTage:DEViation?
<
n
>, <
n-1
> Queries standard deviation of voltage
measurement
136
:CALCulate:STATistics:RESistance:CP?
<Cp>, <CpK> Queries process capability indices of
resistance measurement
137
:CALCulate:STATistics:VOLTage:CP?
<Cp>, <CpK> Queries process capability indices of
voltage measurement
137
Memory Function
:MEMory:STATe
1/ 0/ ON/OFF Sets the memory function state 137
:MEMory:STATe?
ON/ OFF Queries the memory function state 137
:MEMory:CLEAr
Clears instrument memory 137
:MEMory:COUNt?
0 to 400 Queries the memory data count 138
:MEMory:DATA?
[STEP] Queries the memory data 138
Self-Calibration
:SYSTem:CALibration
Executes self-calibration 139
:SYSTem:CALibration:AUTO
1/ 0/ ON/OFF Sets automatic self-calibration 139
Message ([ ] = optional) Data Formats (Re-
sponse data if a Query)
Description Ref
page
HIOKI BT3564A961-02

Table of Contents