ENGLISH
DHW defrost
87
Heater forced OFF
87
Unit and installation pipes antifreeze protection
8
7
Standard / ECO water pump operation
8
7
Electric heater or boiler emergency mode
87
DHW tank’s heater operation
8
7
! CAUTION
Never turn all DSW4 dip switch pins ON. If this happens, the software of the unit will be removed.
Never activate “Heater Forced OFF” and “Electric heater or boiler emergency mode” at the same time.
DSW5: Additional setting 3
In the cases where the outdoor unit is installed into a location where its own outdoor ambient temperature sensor can not give a
suitable temperature measurement to the system, it is available the 2nd outdoor ambient temperature sensor as accessory. By
means of DSW1&2 setting, the preferable sensor for each circuit can be selected.
Factory setting
Outdoor unit sensor for circuits 1 and 2.
Outdoor unit sensor for circuit 1; Auxiliary sensor for circuit 2.
Auxiliary sensor for circuit 1; Outdoor unit sensor for circuit 2.
Auxiliary sensor instead of outdoor unit sensor for both circuits.
DSW6: Not used
Factory setting
(Do not change)
ELECTRICAL AND CONTROL SETTINGS
PMML0575 rev.2 - 03/2022
95

Table of Contents

Other manuals for Hitachi YUTAKI RWM-2R1E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI RWM-2R1E and is the answer not in the manual?

Hitachi YUTAKI RWM-2R1E Specifications

General IconGeneral
BrandHitachi
ModelYUTAKI RWM-2R1E
CategoryAir Conditioner
LanguageEnglish

Related product manuals