ENGLISH
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
YUTAKI S COMBI
Model Power supply Operation mode Z
max
(Ω)
RWD-(2.0-3.0)RW1E-
220S(-K)
1~ 230V 50Hz
Without electric heaters -
With electric heater -
With DHW tank heater -
With electric and DHW tank heaters 0.29
RWD-(2.0-3.0)RW1E-
220S(-K)
3N~ 400V 50Hz
Without electric heaters -
With electric heater -
With DHW tank heater
-
With electric and DHW tank heaters
-
RWD-(4.0-6.0)NW1E-
220S(-K)
1~ 230V 50Hz
Without electric heaters -
With electric heater 0.28
With DHW tank heater -
With electric and DHW tank heaters 0.19
3N~ 400V 50Hz
Without electric heaters -
With electric heater -
With DHW tank heater -
With electric and DHW tank heaters -
YUTAKI S80
Indoor unit alone
Model Power supply Operation mode Z
max
(Ω)
RWH-4.0VNFE
1~ 230V 50Hz
Without DHW tank heater 0.31
With DHW tank heater 0.20
RWH-5.0VNFE
Without DHW tank heater 0.27
With DHW tank heater 0.18
RWH-6.0VNFE
Without DHW tank heater 0.24
With DHW tank heater 0.17
RWH-4.0NFE
3N~ 400V 50Hz
Without DHW tank heater -
With DHW tank heater 0.38
RWH-5.0NFE
Without DHW tank heater -
With DHW tank heater 0.38
RWH-6.0NFE
Without DHW tank heater -
With DHW tank heater 0.38
ELECTRICAL AND CONTROL SETTINGS
PMML0575 rev.2 - 03/2022
73