Indoor unit in combination with DHW tank
Model Power supply Operation mode Z
max
(Ω)
RWH-4.0VNFWE
1~ 230V 50Hz
Without DHW tank heater 0.31
With DHW tank heater 0.21
RWH-5.0VNFWE
Without DHW tank heater 0.27
With DHW tank heater 0.19
RWH-6.0VNFWE
Without DHW tank heater 0.24
With DHW tank heater 0.17
RWH-4.0NFWE
3N~ 400V 50Hz
Without DHW tank heater -
With DHW tank heater 0.41
RWH-5.0NFWE
Without DHW tank heater -
With DHW tank heater 0.41
RWH-6.0NFWE
Without DHW tank heater -
With DHW tank heater 0.41
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the YUTAKI S80 domestic hot water tank accessory
“DHWS(200/260) S-2.7H2E(-W)”.
Monobloc system - R410A YUTAKI M
Model Power supply Operation mode Z
max
(Ω)
RASM-4VNE
1~ 230V 50Hz
Without DHW tank heater 0.24
With DHW tank heater 0.17
RASM-5VNE
Without DHW tank heater 0.24
With DHW tank heater 0.17
RASM-6VNE
Without DHW tank heater 0.24
With DHW tank heater 0.17
RASM-4NE
3N~ 400V 50Hz
Without DHW tank heater -
With DHW tank heater 0.31
RASM-5NE
Without DHW tank heater -
With DHW tank heater 0.31
RASM-6NE
Without DHW tank heater -
With DHW tank heater 0.30
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.
Monobloc system - R32 YUTAKI M
Model Power supply Operation mode Z
max
(Ω)
RASM-2VRE
1~ 230V 50Hz
- -
With DHW tank heater 0.30
RASM-3VRE
- 0.43
With DHW tank heater 0.24
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.