EasyManua.ls Logo

Honeywell Apex - Enclosure and Physical Details; Configuration Options; Certification and Approvals

Honeywell Apex
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
102
MAN0604_Issue 09_02-2013 Apex
2110M8030
APPENDIX A - SPECIFICATIONS
A.1.8 Enclosure
Physical: TheTransmitterUnithas:
OnethreadedholeinthebaseformountingtheCertiedSensor
-M20(European)or3/4”NPT(NorthAmericanversions)
TwothreadedholesinthebasetoaccepttwocertiedM25cable
glands (European) or two
3/4”NPTconduitttings(NorthAmerican
versions).
Provision is made to attach a tag carrying an ID number.
The enclosure materials for Apex are electro-polished grade 316
stainless steel (to BS3146 ANC 4B FM/BS3146 ANC 4C FM) and
ZincAlloy.
Size: 140mmwidex150mmhighx152mmdeep.
Weight: 4000gm.
Mountings: ProvisionfortwoM10bolts,centres68mmapart.
IngressProtection IP67toBSEN60529:1992,Degreesofprotectionprovidedby
(Transmitter Unit with enclosures (IP code).
CertiedSensortted)
A.1.9 Conguration
TheTransmitterUnitcanbeconguredduringinstallationandoperationtoacceptanyofthe
CertiedSensorsitiscompatiblewith(seethegas/cartridgetablesinsectionA.2).
A.1.10 Certication and Approvals
Hazardous Area Certications
Transmitter Unit:
ATEX: II 2 G D Ex d ia IIC Ex tD A21 IP67
Operatingtemperaturecodes:
T135°C(Tamb-40to+80°C)
T100°C(Tamb-40to+55°C)
Baseefa08ATEX02523
UL: Approvals by UL
Class I, Division 1, Groups B, C, D
Operatingtemperaturecodes:
T4(Tamb-40to+80°C)
T5(Tamb-40to+55°C)
CSA: Approvals by CSA
Class I, Division 1, Groups B, C, D
T4(Tamb-40to+75°C)
T5(Tamb-40to+55°C)
TransmitterUnitCertiedtoCSA C22.2 No.
152onlywhenCertiedSensoristtedwithspecic
cartridges. See A.2 Cartridges, Flammable SG16 - US/Rest of the
worldversion(page108).

Table of Contents