SAFETY
CAUTIONS
1.  Only the combustible gas detection portion of this instrument has been assessed for 
performance by CSA.
2.  Refer to local or national regulations relative to installation and use at the site.
  Note:  This equipment is designed and constructed to prevent ignition sources arising, 
  even in the event of frequent disturbances or equipment operating faults. The 
  electrical input is protected with a fuse.
3.  Installation should consider not only optimum siting for gas detection related to potential 
leak points, gas characteristics and ventilation but also placement where the potential for 
mechanical damage is minimised or avoided.
4.  Observe precautions for handling electrostatic discharge sensitive devices when accessing 
the interior of the Transmitter Unit.
5. Calibrationproceduresshouldonlybeperformedbyqualiedpersonnel.
6.  Ensure that when forcing signals on the Transmitter Unit’s output that the effects on the 
network and controller are understood.
7. EnsurethattheApexTransmitterUnitorJunctionBoxamepathisnotdamagedduring
dismantlingprocedures.Theamepathisformedbythematingsurfacesoftheunit’stop 
and base.
8.  During installation/maintenance only use the supplied parts. Replacement with alternatives 
willinvalidatecertication.
9. Exposuretouorinatedhydrocarbonsorsiliconeswillpoisonthesensorbeadsoncatalytic
sensor cartridges. If a sensor is known to have been poisoned then it must be re-calibrated. 
Ifnotsurethenowgasoverthesensorandifthereadingisincorrectre-calibratewithinthe
cartridge’s tolerance value.
10.OnlycartridgeswiththefollowingpartnumberscanbettedtotheCertiedSensor: 
 2110B30x0,31x0,32x0,33x0,34x0,35x0series 
  2110B3700-2110B3999range
 Note: CertiedtoCSA C22.2 No. 152onlywhenttedwithspeciccartridges.  
 Seespecicationsfordetails.
11.Donotusetheunitwherethetemperatureislowerthan-40°C(-40°F)orhigherthan 
+65°C(149°F).
12. Exposures to gas above the recommended range may result in ambiguous readings and 
may require subsequent re-calibration of the sensor.
13. Review cartridge data sheets for operating temperatures and humidities, which are 
determined on a cartridge by cartridge basis.
14.Disposeofinaccordancewithlocaldisposalregulations.Materialsused:
  Transmitter Unit 
MainBody:   StainlessSteel 
UserInterface:   ZincAlloy
  Certied Sensor     
MainBody:   StainlessSteel
  Certied Junction Box   
Mainbody:   Stainlesssteel