Addenda Required: When Required is set, the HF800 only reads UPC-A bar codes
that have addenda.
Addenda Separator: When this feature is On, there is a space between the data
from the bar code and the data from the addenda. When turned Off, there is no
space.
UPC-E
Click the “UPC-E” in the left list then all its related parameters will be shown on the
right.
Redundant times: output the decode result only when got identical barcodes
information for specific times.
E0 / E1 Decoding: Most U.P.C. bar codes lead with the 0 number system. For these
codes, use UPC-E0.If you need to read codes that lead with the 1 number system,
use the UPC-E1 On selection.
E Expand: UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format.
E Check Digit Transmit: Check Digit specifies whether the check digit should be
transmitted at the end of the scanned data or not.
UPC-E0 Leading Zero: This feature allows the transmission of a leading zero (0) at
the beginning of scanned data.
2/5 Digit Addenda: This selection adds 2 or 5 digits to the end of all scanned UPC-E
data.
Addenda Required: When Required is set, the HF800 only reads UPC-E bar codes
that have addenda.
Addenda Separator: When this feature is On, there is a space between the data
from the bar code and the data from the addenda. When turned Off, there is no
space.