8. Use of the SHC1 Handheld Interrogator
Read this chapter if the SHC1 Handheld Interrogator is being used to communicate
with Searchpoint Optima Plus.
8.1 Introduction
ThischapterexplainshowtoconnecttheSHC1HandheldInterrogatortotheSearchpointOptimaPlusand
how to operate it. It also provides the menu structure for use with Searchpoint Optima Plus.
TheSHC1HandheldInterrogatorisaportable,intrinsicallysafedevicewhichcanbeusedtocalibrate,test
andcommissionallofHoneywellAnalyticsSearchpointandSearchlineopticalgasdetectionproducts.
TheSHC1HandheldInterrogatorusesthedetector’scommunicationslink.
Note:TheSHC1HandheldInterrogatordoesnotreadtheHART
®
communications.
Note:TheHART
®
communicationtakesprecedenceovertheRS485communicationusedbytheSHC1
HandheldInterrogator.IftheSearchpointOptimaPlusisbeingpolledsimultaneouslybyaHART
®
host,
temporarycommunicationerrorsmaybeexperiencedbytheSHC1HandheldInterrogator.
8.2 SHC1 Connection
WARNING
DonotattempttoconnecttheSHC1HandheldInterrogatordirectlytoSearchpointOptimaPlus.
AlwaysuseaDVC100seriesterminationunit,ortheSHCProtectionDevice.
ConnecttheSHC1HandheldInterrogatortothegasdetectorinoneofthefollowingways:
1. WithaHoneywellAnalyticsDVC100JunctionBox,connecttheInterrogatordirectlytothejunctionbox
via the IS socket.
ESC
Calibrator
Type SHC1
2.WithanyothertypeofjunctionboxusetheSHCProtectionDevice(alsoseeSection4Electrical
Installation).