84
18. Certication and Approvals
18.1 EC Declaration of Conformity
A full EC declaration of conformity is available on the CD accompanying the product. This document lists
the European Standards with which the Searchpoint Optima Plus complies.
18.2 Hazardous Area Certication
18.2.1 ATEX
CerticateNumber: Baseefa13ATEX0296X
II 2 GD Ex d op is IIC Gb Ex tb IIIC Db
T96°C(Tamb-40°Cto+65°C)
T86°C(Tamb-40°Cto+55°C)
IP66/67
Vmax=32VdcPmax=8W
18.2.2 UL
FileNumber: E91044–Vol.1
Class I, Groups B, C and D
(Amb-40°Cto+65°C)
Vmax=32VdcPmax=8W
18.2.3 InMetro (Brazil)
CerticateNumber: TÜV12.1017X
BR-ExdIICT5IP66/67(-40°C≤ Ta ≤+55°C)
BR-ExdIICT4IP66/67(-40°C≤ Ta ≤+65°C)
Umax = 32 Vcc
Pmax=8W
18.2.4 CSA
Certicatenumber: 1139164
ClassI,Div1,GroupsB,CandDTamb-40°Cto+65°C
Vmax=32VdcPmax=8W
18.2.5 FM
Certicatenumber: 3015165
Class I, Division 1, Groups B, C and D
18.2.6 CU-TR Ex (Eurasian) Approval – XTC Version (Russia)
Certicatenumber: TCRUC-US.ГБ08.B.01294
№TCRUC-US.ГБ08.B.01294(MadeinGreatBritain)
№TCRUC-RU.ГБ08.B.01692(MadeinRussia)
1ExdbopisbIICT86°C/T96°CX,
ExtbIIICT86°C/T96°CX
(Tamb-60°Cдо+65°C)