54
9. Type in the new password and press Enter.
Note:SomeHART
®
handheld devices contain a default password or hold a previously used password.
Ensure that the desired password is typed in before pressing Enter.
10.Thedisplayshowsaconrmationmessage,pressOK.
11.ProceedtoCongureHART
®
Operation during Fault, step 3, or press Back to return to the Device
Setup menu.
12.3.2 Congure HART
®
Operation during Fault
Searchpoint Optima Plus is shipped with the Fault output current level set to < 1 mA. If the unit enters
aFaultcondition,theHART
®
communicationswillnotwork(HART
®
communications require > 1 mA to
operate).TheFaultoutputcurrentlevelcanbechangedto1mAsothatHART
®
communications remain
active during a Fault condition.
1. Select Device Setup.
2. Select User Conguration.
3. Select HART During Fault.
4. Select HART ACTIVE and press Enter.
5. Press Send to send the information to Searchpoint Optima Plus.
6. Proceed to Set the Time and Date, step 3, or press Back to return to the Device Setup menu.
12.3.3 Set the Time and Date
SearchpointOptimaPlushasarealtimeclock,whichisfactorysettoUKtime.Itcanbeadjustedtolocal
time.
1. Select Device Setup.
2. Select User Conguration.
3. Select Set Time.
4. Enter the correct time (24 hour format) and press Enter.
5. Thedisplayshowsaconrmationmessage,pressOK.
6. Select Set Date.
7. Enterthecorrectdate(dd/mm/yyyyformat)andpressEnter.
8. Thedisplayshowsaconrmationmessage,pressOK.
9. ProceedtoCongureWarning,InhibitandOverrangeSignalLevels,step3,orpressBack to return
to the Device Setup menu.
12. Commissioning using
HART
®