EasyManua.ls Logo

horsch LEEB LT - Agitator; Illuviation Valve; Circulation; Spraying; Residue Drain

horsch LEEB LT
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.7 Agitator
¾ Set the ball valve on the suction side to
Suction water/spraying mixture from spraying mixture
container
and the ball valve on the pressure side to
Agitator
.
¾ Switch on the PTO-shaft. Stirring is done with full power.
¾ The intensity of the agitator can be manually adjusted via the directional valve during circula-
tion/spraying. To do so, the ball valve of the pressure side must be set to
Circulation/spraying
.
6.8 Illuviation valve
¾ Illuviate medium during the 󰘰lling process: Set the ball valve on the suction side to
Fill spraying
mixture container via suction connection
and the ball valve on the pressure side to
Illuviation valve
.
¾ Illuviate medium while the spraying mixture container is full: Set the ball valve on the suction
side to
Suction water from spraying mixture container
and the ball valve on the pressure side
to
Illuviation valve
.
¾ Switch on the PTO-shaft.
¾ Turn o󰘯 the PTO-shaft again after all medium was 󰘱ushed in and the illuviation valve cleaned.
6.9 Circulation / spraying
¾ Set the ball valve on the suction side to
Suction water/spraying mixture from spraying mixture
container
and the ball valve on the pressure side to
Circulation/spraying
.
¾ Switching on the PTO-shaft activates the piston diaphragm pump.
¾ Activate the circulation on the terminal.
¾ The intensity of the agitator can be set with the manual valve during circulation/spraying.
6.10 Residue drain
¾ Place a suitable collecting vessel under the residue drain and open the ball valve.
¾ Set the ball valve on the suction side to
Residue drain
and the ball valve on the pressure side
to
Circulation/spraying
.
¾ Set the ball valve of the suction side to
Suction water from spraying mixture container
after
spraying mixture container and the lines are drained.
¾ Close the ball valve and dispose of the collected residual solution according to regulation.
108 MF