3.2.4 Cleaning with machines of the variant CCS
F
a
b
c
d
e
(a) Perform continuous inside cleaning
(CCS) of the machine
(b) Blow spray nozzles out with air.
Spraying mixture residues or moisture will
be forced out (optional)
(c) Putting the sprayer system into winter
storage
¾ See Chapter Spraying system winter storage
(d) Cleaning the spraying mixture container
(e) Disrupting the circulation from the folding
boom to the spraying mixture container
3.2.4.1 Continuous inside cleaning
g
f
a
b
c
d
e
(a) Start/stop cleaning. At the end of the pro-
cess, the green display will go out.
¾ Cleaning stops by pressing button a or
it stops on its own when the solution
tank is empty and the folding boom
pressure is 0 bar.
(b) Nozzles open
(c) Cleaning left border nozzle
(d) Cleaning right border nozzle
(e) Cleaning left edge nozzle
(f) Cleaning right edge nozzle
(g) Filling level spraying mixture container
¾ Each border and edge nozzle must be se-
lected individually to clean it. The border
or edge nozzle can be selected per side.
22 23