3.2.4.4 Spraying mixture container cleaning
a
b
The function pumps fresh water into the spray-
ing mixture container for internal cleaning to
prevent drying of the spraying mixture.
(a) Manual cleaning of the spraying mixture
container when the machine is stopped
¾ The softkey must be pressed and held
for this period.
(b) Filling level spraying mixture container
3.2.5 Cleaning with machines of the variant ECO
F
a
(a) Disrupt the circulation from the folding
boom to the spraying mixture container.
¾ The return line from the spraying mixture
container closes. As a result, no more fresh
water can ow back into the spraying mix-
ture container, e.g. during cleaning (with
nozzles closed). In addition, pressure lter
ushing is disabled.
An info message is displayed on the
terminal as long as the function is active
(circulation deactivated). The function is
always deactivated after restarting (circula-
tion active).
24 25