Pressure check
¾ Fill the spraying mixture container with approx. 200 litres of water.
¾ Switch on the circulation and adjust to approx. 2 bar. Check the pump pressure (g); no pressure
may be applied to the agitator (h) and cleaning (i). Now deactivate the circulation again.
¾ Switch on the agitator on the external control terminal. Check the pressure on the agitator (h).
No pressure may be applied to the cleaning pump (i). Now deactivate the agitator again.
¾ Contact HORSCH Service in case of any deviation.
¾ If pressure is indicated while the spraying pump is switched o󰘯, the pressure sensor must be
subjected to teaching again. Teach procedures must be carried out by HORSCH service sta󰘯!