107
NOTE:
The AC power frame and power monitor module are integrated to the chassis of 12500 AC models, so
you do not need to order them. You must order the PEM and AC power supplies yourself.
The DC power frame and power monitor module are inte
g
rated to the chassis of 12500 DC models, so
you do not need to order them. You must order the DC power supplies yourself (PEM is not needed for
the DC power system).
Table 41 Electrical parameters of power supplies
Power supply
Rated input voltage
range
Max input voltage
range
Max
input
current
Max output power
AC power
supply
100 VAC to 120 VAC;
50 Hz or 60 Hz
200 VAC to 240 VAC;
50 Hz or 60 Hz
90 VAC to 264
VAC; 47 Hz to 63
Hz
13.3 A
1200 W (100 VAC to 120
VAC)
2000 W (200 VAC to 240
VAC)
DC power
supply
–48 VDC to –60 VDC
–42 VDC to –72
VDC
60 A 1800 W
Table 42 16A AC power cords used in different countries or regions
1
Connector
type
Code (Length)
Countries or regions
where the type of
power cords conforms
to local safety
regulations and can be
used legally
Other countries or
regions using this type of
power cords
Countries or
regions seldom
using this type of
power cords
I type
04043396 (3
m, i.e., 9.8 ft)
Mainland China
Connector outline Power cable outline Connector outline
2
Connector
type
Code (Length)
Countries or regions
where the type of
power cords conforms
to local safety
regulations and can be
used legally
Other countries or
regions using this type of
power cords
Countries or
regions seldom
using this type of
power cords
B type
0404A063 (3
m, i.e., 9.8 ft)
Canada and U.S.A
Mexico, Argentina,
Brazil, Columbia,
Venezuela, Thailand,
Peru and Philippines
Connector outline Power cable outline Connector outline