# Display the electrical label information about the transceiver plugged in interface GigabitEthernet
3/0/4.
<Sysname> display transceiver manuinfo interface gigabitethernet 3/0/4
GigabitEthernet3/0/4 transceiver manufacture information:
Manu. Serial Number : 213410A0000054000251
Manufacturing Date : 2012-09-01
Vendor Name : HP
Table 24 Command output
Field Descri
p
tion
Manu. Serial Number
Serial number generated during commissioning and testing of the transceiver
module.
Manufacturing Date Commissioning date.
Diagnosing transceiver modules
The switch provides the alarm function and digital diagnosis function for transceiver modules. When a
transceiver module fails or is not operating normally, you can check the alarms present on the transceiver
module to identify the fault source or examine the key parameters monitored by the digital diagnosis
function, including the temperature, voltage, laser bias current, TX power, and RX power.
To diagnose transceiver modules, execute the following command in any view:
Task Command Remarks
Display alarms present on the
transceiver in a specified
interface
display transceiver alarm interface
[ interface-type interface-number ]
Available for all transceivers
If no error occurs, None is
displayed.
Display the present measured
values of the digital diagnosis
parameters for the transceiver
in a specified interface
display transceiver diagnosis
interface [ interface-type
interface-number ]
Available for all transceivers.
# Display the alarm information about the transceiver plugged in GigabitEthernet 3/0/1.
<Sysname> display transceiver alarm interface GigabitEthernet 3/0/1
GigabitEthernet3/0/1 transceiver current alarm information:
RX loss of signal
RX power low
Table 25 shows the alarm information that may occur to the commonly used transceivers.
Table 25 Command output
Field Remarks
transceiver current alarm information Alarms present on the transceiver module.
SFP
RX loss of signal Received signals are lost.
TX fault Transmission error.
RX power high The received optical power is high.