75
Task Command
Display key parameters of the transceiver
in a specified interface
display transceiver interface [ interface-type interface-number ]
Display part of the electrical label
information of transceiver in a specified
interface
display transceiver manuinfo interface [ interface-type
interface-number ]
# Display the main parameters of the transceiver plugged in interface GigabitEthernet 3/0/3.
<Sysname> display transceiver interface gigabitethernet 3/0/3
GigabitEthernet3/0/3 transceiver information:
Transceiver Type : 1000_BASE_SX_SFP
Connector Type : LC
Wavelength(nm) : 850
Transfer Distance(m) : 550(50um),270(62.5um)
Digital Diagnostic Monitoring : YES
Vendor Name : HP
Ordering Name : JD118B
Table 23 Command output
Field Descri
tion
Connector Type
Type of the connectors of the transceiver:
• SC—Fiber connector, developed by NTT
• LC—1.25 mm/RJ-45 optical connector developed by Lucent.
• RJ-45
• CX 4
Wavelength(nm)
• Fiber transceiver—Central wavelength (in nm) of the laser sent. If the
transceiver supports multiple wavelengths, every two wavelength values are
separated by a comma.
• Copper cable—Displayed as N/A.
Transfer distance(xx)
Transfer distance, where "xx" represents the distance unit: km (kilometers) for
single-mode transceivers and m (meters) for other transceivers.
If the transceiver supports multiple transfer medium, every two values of the
transfer distance are separated by a comma. The transfer medium is included in
the bracket following the transfer distance value. The following are the transfer
media:
• 9 um—9/125 μm single-mode optical fiber
• 50 um—50/125 μm multi-mode optical fiber
• 62.5 um—62.5/125 μm multi-mode optical fiber
• TP—Twisted pair
• CX4—CX4 cable
Digital Diagnostic
Monitoring
Support for the digital diagnosis function:
• YES—Supported
• NO—Not supported
Ordering Name Product code.