EasyManuals Logo

HP 12500 Series User Manual

HP 12500 Series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #130 background imageLoading...
Page #130 background image
124
(4) IEC standard socket It is used to connect to the power supply in the equipment room through a
power cord.
(5) Overload automatic protector The protector automatically opens the electric circuit when the current
exceeds the threshold and closes the electric circuit when the current drops
below the threshold.
(6) Multifunctional socket It is used to connect the power supply of the switch.
Installing a lightning protector for a network port
IMPORTANT:
Read the instructions for the lightning protector carefully before you install it.
If part of the network cable of a 10/100/1000 Mbps RJ-45 copper Ethernet port must be routed
outdoors, connect a lightning protector to the cable before you plug the cable into the port.
HP recommends that you install lightning protector for 10/100/1000 Mbps RJ-45 copper Ethernet ports.
The switch does not come with any lightning protector.
Required tools
Phillips or flat-blade screwdriver
Multimeter
Tilted wire cutter
Installation procedure
To install a lightning protector:
1. Use a double-faced adhesive tape to stick the lightning protector onto the switch chassis, and make
sure it is as close to the grounding screw of the switch as possible.
2. Measure the distance between the protector and the grounding screw of the switch, cut the ground
wire of the protector as appropriate, and securely tighten the ground wire to the grounding screw
of the switch.
3. Use the multimeter to measure whether the ground wire of the protector contacts well with the
grounding screw of chassis.
4. Insert the outdoor network cable into the protector's IN end, and the cable connected to the switch
into the OUT end, and look at the indicators on the lightning protector to verify that the connection
is correct.
5. Use nylon ties to bundle the cables neatly.
Installation precautions
The performance of the port lightning protector may be affected in the following cases:
The port lightning protector is installed in reverse direction. Connect the IN end to the outdoor
network cable and the OUT end to the network port on the switch.
The port lightning protector is not well grounded. After the connection, use the multimeter to confirm
that the ground wire for the protector is as short as possible to ensure its good contact with the
grounding screw of the switch.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 12500 Series and is the answer not in the manual?

HP 12500 Series Specifications

General IconGeneral
BrandHP
Model12500 Series
CategorySwitch
LanguageEnglish

Related product manuals