78
Field Remarks
Transceiver info I/O error Transceiver information read and write error
Transceiver info checksum error Transceiver information checksum error
Transceiver type and port configuration mismatch
The type of the transceiver module does not match the
port configuration.
Transceiver type not supported by port hardware
The port does not support this type of transceiver
modules.
# Display the currently measured values of the fault detection parameters of the transceiver plugged in
interface GigabitEthernet 3/0/2.
<Sysname> display transceiver diagnosis interface gigabitethernet 3/0/2
GigabitEthernet3/0/2 transceiver diagnostic information:
Current diagnostic parameters:
Temp(°C) Voltage(V) Bias(mA) RX power(dBm) TX power(dBm)
36 3.31 6.13 -35.64 -5.19
Table 26 Command output
Field Descri
p
tion
transceiver diagnostic information
Digital diagnosis information of the transceiver module on the
interface.
Temp.(°C) Digital diagnosis parameter—Temperature, in °C, accurate to 1°C.
Voltage(V) Digital diagnosis parameter—Voltage, in V, accurate to 0.01 V.
Bias(mA)
Digital diagnosis parameter—Bias current, in mA, accurate to 0.01
mA.
RX power(dBm)
Digital diagnosis parameter—RX power, in dBm, accurate to 0.01
dBm.
TX power(dBm)
Digital diagnosis parameter—TX power, in dBm, accurate to 0.01
dBm.