1. Update the sgen driver:
# update_drv a I scsiclass,0c sgen
NOTE:
Lowercase c is mandatory.
2. Verify the sgen alias setting:
#egrep sgen /etc/driver_aliases
Example:
# rep sgen /etc/driver_aliases
sgen "scsa,08.bfcp"
sgen "scsa,08.bvhci"
sgen "scsiclass,0c"
Enable iSCSI target discovery
Solaris supports three iSCSI target discovery methods:
SendTargets
Static
iSNS
This section describes SendTargets discovery only. For information on static and iSNS discovery, see
http://docs.sun.com/app/docs/doc/817-5093/fqnlk?l=en&=view.
To enable iSCSI target discovery:
1. Enter the following command:
# iscsiadm modify discovery t enable
2. Verify that SendTargets is enabled:
# iscsiadm list discovery
3. The MPX200 has multiple iSCSI ports available to the Solaris iSCSI initiator. To discover the
targets available, enter the following command for each iSCSI port IP address that the iSCSI
initiator will access:
#iscsiadm add discovery-address iscsi port IP address
4. Verify the discovery address entries:
#iscsiadm list discovery-address
MPX200 Multifunction Router 87

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 6400/8400 - Enterprise Virtual Array and is the answer not in the manual?

HP StorageWorks 6400/8400 - Enterprise Virtual Array Specifications

General IconGeneral
BrandHP
ModelStorageWorks 6400/8400 - Enterprise Virtual Array
CategoryStorage
LanguageEnglish

Related product manuals