Specifications
Environmental specifications
Specification Value
Temperature range
1
—
Operating 10°C to 35°C (41°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)
—
Operating 8% to 90%
28°C (824°F), maximum wet bulb temperature
Nonoperating
5% to 95%
387°C (1017°F), maximum wet bulb temperature
1
All temperature ratings shown are for sea level. An altitude derating of 10°C per 305 m (18°F per 1000 ft) to 3050 m (10000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
• 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 10°C per every
175 m (18°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10000 ft)
• Redundant fans are required when the ambient temperature reaches 35°C (95°F) to 40°C (104°F).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise website (http://
www.hpe.com/servers/ASHRAE).
Mechanical specifications
Dimension (with feet/bezel)
Value
Height 4400 cm (1732 in)
Depth 4805 cm (1892 in)
Width 1950 cm (768 in)
Weight (approximate)
Minimum (one drive, power supply, and processor installed)
135 kg (2982 lb)
Maximum (all drives, power supplies, and processors installed)
250 kg (5500 lb)
Specifications 130