To replace the component, reverse the removal procedure.
Removing and replacing the HPE NS204i-p NVMe OS Boot Device
option
Removing and replacing the boot device
Procedure
1.
Observe the following alerts:
CAUTION: The boot device and the drives installed on the boot device are not hot-pluggable. To remove the
boot device, or a drive from the boot device, you must first power down the server.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
2.
Back up all server data.
3.
Power down the server.
4.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Do one of the following:
Server in rack mode:
Remove the server from the rack.
Server in tower mode: Position the tower server for hardware configuration.
7.
Remove the access panel.
Removal and replacement procedures
59