To replace the component, reverse the removal procedure.
Removing and replacing the four-bay LFF non-hot-plug drive cage
CAUTION: To prevent improper cooling and thermal damage, do not operate the enclosure unless all device bays
are populated with either a component or a blank.
Prerequisites
Before you perform this procedure, make sure that you have the T-15 Torx screwdriver available.
Procedure
1.
Power down the server.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Disconnect all peripheral cables from the server.
4. Do one of the following:
• Server in rack mode:
Remove the server from the rack.
• Server in tower mode: Position the tower server for hardware configuration.
5.
Remove the access panel.
6. Remove the front bezel.
7. Remove the PCI air bale.
8.
Remove the system air bale.
9. Disconnect all existing drive cables.
Removal and replacement procedures