7. Connect each power cord to the power source.
8.
Power up the server.
9.
Enable the increased cooling function.
The installation is complete.
Enable the increased cooling function
The server generates more heat when it is installed in a rack. To maintain proper cooling, increase the fan speed.
Procedure
1.
From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Advanced
Options > Fan and Thermal Options > Thermal Configuration.
2.
Select Increased Cooling
3.
Save your setting.
Power up the server
To power up the server, use one of the following methods:
Press the Power On/Standby button.
Use the virtual power button through iLO.
Removing and replacing a drive blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
Removal and replacement procedures 43