3. Disconnect all peripheral cables from the server.
4. Do one of the following:
• Server in rack mode: Remove the server from the rack.
• Server in tower mode:
Position the tower server for hardware configuration.
5. Remove the access panel.
6. Remove the PCI air bale.
7.
Remove the system air bale.
8. Remove the USB device from the internal USB port.
To replace the component, reverse the removal procedure.
Removing and replacing the non-hot-plug power supply
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
Removal and replacement procedures