EasyManua.ls Logo

Huawei IPC6221-VRZ-SP - Page 57

Huawei IPC6221-VRZ-SP
126 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 6-5 Parameter description
Parameter Description
Alarm check interval Time interval at which the system checks for new alarms. The
system then reports detected alarms to the surveillance platform.
NOTE
l The MTU value is an integer ranging from 1 to 256. The default
value of is 5.
l Only one alarm is reported if an object keeps moving in the
surveillance range of the camera within a single alarm check interval.
This is to avoid repeated alarms.
Sensitivity Indicates the sensitivity of motion detection.
NOTE
l The MTU value is an integer ranging from 1 to 5. The default value
of is 3.
l A larger value indicates higher sensitivity. To detect slight motion, it
is recommended that you set the sensitivity to a larger value.
Step 6 Click Save.
NOTE
l To delete a motion detection area, select the motion detection area on the live video image and click
Delete.
l To delete all motion detection areas, click Delete all.
----End
IPC6221-VRZ-SP
Configuration Guide
6 Setting Video Parameters
Issue 02 (2016-04-06) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
51