Heats Setup - Control Page 1 111
User Guide v 1.0 — February 2020 System Setup
Figure 10-3 Heats Setup - Control Page 1
Table 10-3 System Setup Screen - Heats Setup - Control Page 1
Item Description
Manual Standby Duration
Timer
The zone temperature decreases for a given time duration or until
a set standby temperature is achieved.
Manual Boost Duration Timer The zone temperature increases for a given time duration or until
a set boost temperature is achieved.
Remote Standby Duration
Timer
When an external signal has activated the remote standby mode,
the system temperature decreases to the remote standby
setpoint for the duration of the timer setting.
Remote Standby Delay Timer When an external signal has activated the remote standby mode,
the system waits for a set time interval (delay period) until it starts
a decrease in temperature to the remote standby setpoint.
Remote Standby Input Mode The standby setting is enabled by one of three settings: Trigger,
On/Off, or a Direct signal.
Trigger: Includes a delay timer and duration timer. If the D/I signal
is not sensed, Standby or Boost mode continues until the duration
timer elapses.
On/Off: Includes a delay timer. If the D/I signal is not sensed, the
controller returns to the running state.
Direct: The system changes to Standby until the input signal is not
active. If the input signal is active when the system is started it will
immediately go into Standby mode. Includes a delay timer.