Performing maintenance
FCU flushing
NOTICE
Impermissible flushing media
The FCU will be destroyed
Flush the FCU with low-viscosity mineral oils or mineral oil-based
raffinates (e.g. diesel) whose flash point is higher than 55°C / 131°F.
Never flush the FCU with universal thinners or other degreasing fluids.
Flush the FCU after each use, but at least daily, with cleaned mineral oil.
Rinse the FCU immediately if you measure unfiltered oil or oil with a viscosity
> 200 mm²/s or if the readings seem unusually high or low.