OperatiOn
4-38 HPR400XD Auto Gas 806160
Mild steel Fine Feature Cutting
30 A to 260 A
Metric
Material
Thickness
Current Select Gases Set Preflow Set Cutflow
Arc
Voltage
Torch-
to-Work
Distance
Cutting
Speed
Initial Pirece
Height
Pierce
Delay
Time
mm Amps
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Volts mm mm/m mm
Factor
%
Seconds
3
30 O
2
O
2
78 75 94 7
119
1.5
1160
2.7 180
0.5
4 124 905 0.7
5 125 744 0.9
6 128 665 1.0
5
50 O
2
O
2
70 30 81 14
123 1.5 1200 3.0
200
0.4
6 128 2.0 950 4.0 0.5
7
80* O
2
Air 48 23 78 25
119
1.5
2286
4.1 267
0.4
8 2240
9 121 1987
0.5
10 122 1733
10
130 O
2
Air 32 32 84
27 129 2.3 2437 6.1 267 0.3
12 25 132 2.5 1935 6.6 260 0.5
15
200 O
2
Air 23 42 74 15
130 2.0 1778
8.1
400 0.6
16
20 132 2.3 1678 356 0.8
20
260 O
2
Air 22 49
80
47 157 2.3 2032
8.9
389 0.6
22
49
162
3.6
1905
250
0.7
25 84 168 1651 0.8
Note: *The pierce complete signal must be turned off for the 80 A processes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen