EasyManuals Logo

Hypertherm HyPerformance Plasma HPR400 User Manual

Hypertherm HyPerformance Plasma HPR400
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #141 background imageLoading...
Page #141 background image
OperatiOn
HPR400XD Auto Gas 806160 4-41
Mild steel
O
2
Plasma / O
2
Shield
30 A
220194220747 220192220754 220180220193
* Pierce complete is recommended for these thicknesses.
Note: Air must be connected to use this process. It is used as the preflow gas.
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm Factor % Seconds
O
2
O
2
78
17
94
17
0.5 114
1.3
5355
2.3
180
0.1
0.8 115 4225 0.2
1 116 3615
0.31.2 117 2865
1.5 119 2210
35
7
2 120
1.5
1490
2.7
0.4
2.5 122 1325
75
3* 123 1160 0.5
4* 125 905 0.7
6* 128 665 1.0
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in Factor % Seconds
O
2
O
2
78
17
94
17
0.018
114
0.05
215
0.09
180
0.1
0.024 200
0.030 115 170 0.2
0.036 116 155
0.30.048 117 110
0.060 119 85
35
7
0.075 120
0.06
60
0.11
0.4
0.105 122 50
75
0.135* 123 40 0.5
3/16*
128
30 0.7
1/4* 25 1.0
English
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 15 2.5 0.10 6350 250 105
Ar Air 90 10 90 10 9 2.5 0.10 2540 100 80
Marking
Flow rates – lpm/scfh
O
2
Air
Preflow 0 / 0 43 / 90
Cutflow 25 / 52 0 / 0
220340

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen