OperatiOn
HPR400XD Auto Gas – 806160 4-41
Mild steel
O
2
Plasma / O
2
Shield
30 A
220194220747 220192220754 220180220193
* Pierce complete is recommended for these thicknesses.
Note: Air must be connected to use this process. It is used as the preflow gas.
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm Factor % Seconds
O
2
O
2
78
17
94
17
0.5 114
1.3
5355
2.3
180
0.1
0.8 115 4225 0.2
1 116 3615
0.31.2 117 2865
1.5 119 2210
35
7
2 120
1.5
1490
2.7
0.4
2.5 122 1325
75
3* 123 1160 0.5
4* 125 905 0.7
6* 128 665 1.0
Metric
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in Factor % Seconds
O
2
O
2
78
17
94
17
0.018
114
0.05
215
0.09
180
0.1
0.024 200
0.030 115 170 0.2
0.036 116 155
0.30.048 117 110
0.060 119 85
35
7
0.075 120
0.06
60
0.11
0.4
0.105 122 50
75
0.135* 123 40 0.5
3/16*
128
30 0.7
1/4* 25 1.0
English
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 15 2.5 0.10 6350 250 105
Ar Air 90 10 90 10 9 2.5 0.10 2540 100 80
Marking
Flow rates – lpm/scfh
O
2
Air
Preflow 0 / 0 43 / 90
Cutflow 25 / 52 0 / 0
220340