OperatiOn
4-40 HPR400XD Auto Gas 806160
Mild steel Fine Feature Cutting
30 A to 260 A
English
Material
Thickness
Current Select Gases Set Preflow Set Cutflow
Arc
Voltage
Torch-
to-Work
Distance
Cutting
Speed
Initial Pirece
Height
Pierce
Delay
Time
in Amps
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Volts in ipm in
Factor
%
Seconds
0.135
30 O
2
O
2
78 75 94 7
123
0.06
40
0.11 180
0.5
3/16 128 30 0.7
1/4 50 O
2
O
2
70 30 81 14 125 0.08 35 0.16 200 0.5
5/16
80* O
2
Air 48 23 78 25
119
0.06
90
0.16 267
0.4
3/8 121 70 0.5
3/8
130 O
2
Air 32 32 84
27 128 0.09 98 0.24 267 0.3
1/2 25 132 0.10 70 0.26 260 0.5
5/8
200 O
2
Air 23 42 74
14
130
0.08
70 0.32
400 0.6
3/4 15 0.09 356 0.8
3/4
260 O
2
Air 22 49
80
47 158 0.09 80
0.35
389 0.6
7/8
49
166
0.14
75
250
0.7
1 84 171 65 0.8
Note: *The pierce complete signal must be turned off for the 80 A processes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen