OperatiOn
HPR400XD Auto Gas 806160 4-85
Aluminum
Air Plasma / Air Shield
45 A
220202220747 220308220756 220180220201
Metric
English
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
mm Volts mm mm/m mm Factor % Seconds
Air Air 35 19 62
49
1.2 130
2.5
4750
3.8
150
0.2
1.5 115 4160
2 113 3865
2.5 110 3675
3 107 2850
33
4 102 1.8 2660 2.7 0.3
6 117 3.0 1695 4.5 0.6
Select
Gases
Set
Preflow
Set
Cutflow
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce
Height
Pierce Delay
Time
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
Plasma
gas
Shield
gas
in Volts in ipm in Factor % Seconds
Air Air 35 19 62
49
0.040 130
0.10
220
0.15
150
0.2
0.051 115 170
0.064 113 160
0.102 110 140
33
0.125 102 0.07 110 0.11 0.3
3/16 114
0.12
90
0.18
0.4
1/4 117 60 0.6
Flow rates – lpm/scfh
Air
Preflow 45 / 95
Cutflow 78 / 165
Marking
Select
Gases
Set
Preflow
Set
Cutflow
Amperage
Torch-to-Work
Distance
Marking
Speed
Arc
Voltage
Amps mm in mm/m ipm Volts
N
2
N
2
10 10 10 10 15 2.5 0.10 6350 250 85
Ar Air 90 10 90 10 12 2.5 0.10 2540 100 75
220340

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen