Page #284 background image
HPR400XD Auto Gas 806160 7-1
Section 7
WIRING DIAGRAMS
Introduction
This section contains the wiring diagrams for the system. When tracing a signal path or ref er enc ing with the Parts List or
Troubleshooting sections, please be aware of the following format to assist you in un der stand ing the wiring diagrams’
organization:
• Sheetnumbersarelocatedinthelowerright-handcorner.
• Page-to-pagereferencingisdoneinthefollowingmanner:
C
SHEET
4-D3
C
SHEET
4-D3
Destination and Source Coordinates refer to letters A-D on the Y-axis of each sheet and numbers 1-4 on the
X-axis of each sheet. Lining up the coordinates will bring you to the source or destination blocks (similar to a road map).
Wiring diagram symbols
Wiring diagram symbols and their identification precede the system wiring diagrams in this section.
Source Connection Source Reference Block Destination Sheet # Destination
Coordinates
Source Sheet No. Source Coordinates Source Reference Block Destination
Coordinates

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen