Page #288 background image
7-5
3 Phase
Power
w/ Ground
Unit 2
Torch Lead Assembly
Ignition Console
Cooling Supply Lead
HF/PS Cable
Unit 1
Power Supply
Gas Power Cable
Torch
Interface
CNC
(Customer Supplied)
1X3 2X1
1X1
Unit 6
Pilot Arc Lead
Plasma Interface Cable
1X4
Unit 5
(Optional Unit)
THC
CNC Interface Cable
Pendant Ext. Cable
(Optional Unit)
Operator
Unit N
Pendant
Lifter
Torch
(Optional Unit)
Unit M
Work Lead
72"
Cooling Return Lead
1X2
Gas Control Cable
Negative Lead
1X5
Motor Drive Cable
CNC Interface Cable
Lifter I/O Interface Cable
1x12
12x1
Unit 7
Cooler
Cooler Control Cable
1X6
12X2
Cooler Power Cable
4X1
Metering Console
3X23X1 3X4
N2
O2
Air
Selection Console
Unit 3
128930
Power Cable
Atm Vent
Unit 4
3X3 4X2 4X3
Gas Control Cable
Ar
F5
H35
H5
1X6
CNC Interface Cable
Workpiece
Plasma
Shield
Cut Gas 2
Cut Gas 1
4 3 2 1
1
A
4 3 2
A
B
C
D
B
C
D
ELEC SCH:HPR400XD POWER SUPPLY W/AUTO
F
013374
SHEET 1 OF 24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen