EasyManuals Logo

Hypertherm HyPerformance Plasma HPR400 User Manual

Hypertherm HyPerformance Plasma HPR400
355 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #291 background imageLoading...
Page #291 background image
7-8
J2.3
J3
21 3 4 5 6 1110987 12
120VAC RTN
POWER DISTRIBUTION
PCB2
041802
+
+
PA RELAY
D2 PA RELAY
D1 CONTACTOR
CONTACTOR
WHT
WHT
BLU
BLU
RED/BLK
RED
CONTACTOR
MARKING SURGE RELAY
12
10
11
9
7
8
6
4
5
3
J2.5 J5
1
2
+
D5 HV XFMR
HV XFMR
+
D7 MARKING SURGE RELAY
MARKING SURGE RELAY
WHT
BLU
BLU
WHT
RED/BLK
RED/BLK
RED/BLK
RED
RED
RED
PILOT ARC RELAY
HF TRANSFORMER
4
3
2
1
CABLE: 123670
A
B
C
4
3 2
D
4
3 2
1
A
B
C
1
D
SHEET
5-D1
Y
SHEET
2-D1
M
SHEET
2-D1
N
SHEET
2-C4
AD
SHEET
18-D3
AC
F
ELEC SCH:HPR400XD POWER SUPPLY W/AUTO
F
013374
SHEET 4 OF 24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm HyPerformance Plasma HPR400 and is the answer not in the manual?

Hypertherm HyPerformance Plasma HPR400 Specifications

General IconGeneral
Duty Cycle100% at 400 A
Cutting Capacityup to 50 mm (2 in)
Output Current30-400 A
Input Voltage200 – 480 V, 3-PH, 50/60 Hz
Gas SupplyOxygen, Air, Nitrogen